BPH-414E 120V

Download PDF

(169.14 KB)

Operating principle

The Bimor's driving force, the bimorph, comprises two parallel piezoelectric wafers. Their nature is to expand or contract depending on the direction of the voltage. Therefore, when an alternating current is applied, one wafer expands then contracts while the other contracts then expands, causing the biomorph to bend. Repeating the cycle creates a pumping action, as the diagram below shows.

Specifications

Current: 30 mA
Flow Rate: 500 ml/min
Outlet Pressure: 350 mbar
Self-Priming Pressure: 120 mbar
Housing Material: PP
Bimorph Material: PP
Valve / O-Ring: EPDM
Weight: 140 g
Suitable Liquids: Potash, Caustic Sodas, Hydrochloric Acids

Flow Rate Characteristics
(click to enlarge)

Durability Graphs (click to enlarge)

Legend
BPH-414E 120V

Cross-Section and Operating Diagram

BPH-414E 120V